Home ProductsLED Stadium Light

1000w High Power Led Flood Light 140lm / W For Stadium Lighting

Certification
China Shenzhen Leyond Lighting Co.,Ltd. certification
China Shenzhen Leyond Lighting Co.,Ltd. certification
Customer Reviews
I am very satisfied with your company in terms of quality.

—— Mr Frank

Hello Ada; I wish you have enoyed your holidays. Yes we tested the sample lamp, and we are very satisfy with the quality.

—— Ms.Valentina

I'm Online Chat Now

1000w High Power Led Flood Light 140lm / W For Stadium Lighting

1000w High Power Led Flood Light 140lm / W For Stadium Lighting
1000w High Power Led Flood Light 140lm / W For Stadium Lighting 1000w High Power Led Flood Light 140lm / W For Stadium Lighting 1000w High Power Led Flood Light 140lm / W For Stadium Lighting

Large Image :  1000w High Power Led Flood Light 140lm / W For Stadium Lighting

Product Details:

Place of Origin: Shenzhen,China
Brand Name: Leyond
Certification: CE RoHS
Model Number: 1000w led flood light

Payment & Shipping Terms:

Minimum Order Quantity: 1 pc
Price: USD1000-USD1300 per unit
Packaging Details: 1pc per carton, foam inside and strong outer carton for export shipping
Delivery Time: 7-10 working days after payment confirmed
Payment Terms: Western Union, T/T,Paypal
Supply Ability: 10000pcs per month
Detailed Product Description
LED Type: CREE XTE 140LM/W LED Driver: 4pcs Meanwell HLG Driver
Power: 1000W Input Volt.: AC100-305V, PF>0.95
CCT: WW 2700-3000K, PW 5000-6000K Warranty: 5 Years Without Worries
Waterproof: IP65 Beam Angle: 90°*50°,90°*10°
High Light:

led stadium lighting

,

high power led floodlight

 

1000w High Power Led Flood Light 140lm / W For Stadium Lighting

 

Available for beam angle: 90x10degree, 90x50degree, high lumens, install height 10-50meters

 

1000W High Power LED Flood Light Specification:

 
Input voltage AC100V~240V
Frequency range 50HZ~60HZ
Total harmonic distortion ≤9%
Power factor ≥0.9
Power efficiency >85%
System consumption 1000W
LED package CREE XTE
LED consumption 1000W
LED Working voltage DC33~39V
LED quantity 440PCS
LED luminous >80100lm
LED luminous efficiency 85~95lm / W
CRI >70
LED Junction temperature ≤85℃
Operational condition Temperature    -30℃~50℃
Humidity        10%~90%RH
Storage temperature -30℃~75℃
Working life-span >50,000H
Beam angle 90°*50°,90°*10°
IP Grad IP65
Housing Glass and AI alloy
Mounting Height Suitable for 10~50m height
 

 

Features:

 

• Full waterproof design IP65

• High transmittance empered glass,transimittan 93% 

• Multible choices for reflctors: 90°*50°,90°*10°, meet the requirement of professional light distribution. 

• By riveting the heatsink to the fins,make the incomparable heatsink housing,The heat from the LEDS is transformed to the fins with massive dissipating area by the 12X8mm heatpipes,reducing the temperature of the LEDS rapidly and extending the life span. 

• Over Current,Over Voltage,Over Heat,Thunder Protection 

• Choice of correlated color temperatures 

• Long lifespan for LED 50,000 hrs 

• Complying with CE,ROHS, No strobing during working, Fast response (no delay) , No mercury vapour , No radiation,No UV,No damage with frequency switching 

 

 

Meanwell Driver for 1000 watt high power led flood light:

 

Driver brand: Meanwell HLG-240 Series X 4pcs
Ac input voltage range 90-305VAC/350VAC/480VAC,127-417VDC/431VDC
Power factor >0.95
Driver Safety standards Passted UL 8750/1012/60950,TUV EN61347/60950-1
Protection function Short circuit, overload, over voltage, over temperature
Emc standard EN55015,EN55022 Class-B,EN61000-3-2  Class-C
Drive IP IP65
Housing Material Aluminum
 

 

1000w High Power Led Flood Light 140lm / W For Stadium Lighting 0

 

Installation: 

 

• Installation tool:A adjustable wrench group.

 

Installation Steps:

 

• Remove the hexagonal screws on the floodlights handle,then adjust the angle you need,finally Tighten Axle Screw, and Locate Screw Tighten Axle Screw.

• Connecting the power line of LED Flood Light to the power supplier ,finish the installation procedure

 

The installation notices:

 

• No necessary using other devices for LED Flood light installation such as stabilizer,regulator and so on 

• Opening the light and lifting the buckle is unallowable.Soaking in the water is unallowable

 

Warning:

 

• Do Not Use Other Devices for LED Floodlight Installation Such as Stabilizer,Regulator …etc

• Do Not Open the Light Engine

• Do Not Soak the Floodlight into Water

• Do Not Light up the System Without Grounding

• Do Not Use Dimmer

 

Applications:

 

Complete lamp can replace high pressure sodium lamp over 1500-2000W.It can instant start,and has long life span,low consumption of energy,and polluting-free.It can be widely used at the stadium,golf course,wharf,square,etc

 

Production:

 

1000w High Power Led Flood Light 140lm / W For Stadium Lighting 1

1000w High Power Led Flood Light 140lm / W For Stadium Lighting 2

 

 

Contact: Leo Loo

Email: sales19@leyond.com.cn

Skype: lysales19

Contact Details
Shenzhen Leyond Lighting Co.,Ltd.

Contact Person: Leo Lu

Tel: +8613006604814

Send your inquiry directly to us (0 / 3000)